DCS-PE DES-1241 Exam Dumps and Certification Test Engine [Q27-Q47]

Share

(PDF) DCS-PE DES-1241 Exam and Certification Test Engine

Use DES-1241 Exam Dumps (2022 PDF Dumps) To Have Reliable DES-1241 Test Engine


For more info about DES-1241 Specialist - Platform Engineer, PowerStore Exam

Dell Education Home

 

NEW QUESTION 27
What is the last step when adding a drive to a Dell EMC PowerStore system?

  • A. Add the drive to the pool
  • B. Backup the keystore
  • C. Zero the drive
  • D. Verify the new drive is seen

Answer: D

Explanation:
Reference:
https://www.dell.com/support/manuals/pk/en/pkbsd1/powerstore-9000t/pwrstr-isg/install-a-25- drive?guid=guid-bddae51e-a561-4e84-bc0a-c2e99a43f033&lang=en-us

 

NEW QUESTION 28
Which component is a CRU?

  • A. Battery Backup Unit
  • B. Base enclosure
  • C. Expansion enclosure
  • D. Nodes

Answer: D

Explanation:
https://www.dellemc.com/content/dam/digitalassets/active/en/unauth/manual-warranty-informations/h4276-emc-prod-warranty-maint-table.pdf

 

NEW QUESTION 29
A Storage Administrator notices a Major alert present in Dell EMC PowerStore Manager relating to data protection. What action within the alert details slide-out panel is helpful in troubleshooting the data protection problem?

  • A. View the Associated Events for earlier related alerts
  • B. Examine Notifications to obtain a list of corrective actions
  • C. Acknowledge the alert to clear and resolve the problem
  • D. Access the Repair Flow link to schedule a support engagement

Answer: B

 

NEW QUESTION 30
A Storage Administrator encounters a Snapshot issue on a Dell EMC PowerStore X system.
The administrator engages support and they determine the Snapshot issue is a known code bug within the OS version of PowerStore code. How can support address the problem in a timely manner?

  • A. Wait for a new full OS release that corrects the code bug
  • B. Upgrade the Snapshot portion of code within the OS
  • C. Upgrade the PowerStore with a hotfix that corrects the code bug
  • D. Disable the Snapshots feature to avoid encountering the code bug

Answer: C

 

NEW QUESTION 31
Which component is only replaceable by qualified personnel?

  • A. 4-Port mezzanine card
  • B. Memory module
  • C. Battery backup unit
  • D. Embedded I/O module

Answer: B

 

NEW QUESTION 32
From where can a data collection be initiated within Dell EMC PowerStore Manager?

  • A. Node, storage resource, and alerts
  • B. Cluster, appliance, and event log
  • C. Appliance, node, and storage resource
  • D. Cluster, appliance, and alerts

Answer: D

Explanation:
Collecting Support Materials can be initiated several ways from PowerStore Manager. Data Collections can be started at the Cluster, Appliance, Storage Resource, and Alerts level.

 

NEW QUESTION 33
Through which network do external hosts connect to the cluster for data access?

  • A. ICM
  • B. Management
  • C. ICD
  • D. Storage

Answer: D

Explanation:
https://topics-cdn.dell.com/pdf/pwrstr-hcg_en-us.pdf

 

NEW QUESTION 34
While on-site installing a Dell EMC PowerStore T system, the node A embedded module management Ethernet port link LED is off. What does this indicate?

  • A. Port speed is 1 GB/s
  • B. No network connection is established
  • C. Network connection is established
  • D. Port speed is 10 GB/s

Answer: B

 

NEW QUESTION 35
Which option is used when running the journalctl command to query log messages regardless of capitalization?

  • A. option -quotes
  • B. option --casesensitive=YES/NO
  • C. option -ignorecase
  • D. option --casesensitive=TRUE/FALSE

Answer: D

Explanation:
https://dl.dell.com/topicspdf/pwrstr-ssg_en-us.pdf

 

NEW QUESTION 36
When planning for a Dell EMC PowerStore T implementation, how many IP addresses are required for the storage network?

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: D

Explanation:
Explanation/Reference: https://topics-cdn.dell.com/pdf/pwrstr-ntwk-plang_en-us.pdf (22)

 

NEW QUESTION 37
During Dell EMC PowerStore startup, both appliance nodes have rebooted in service mode. What must be done first to avoid management software conflicts?

  • A. Return node A to normal mode
  • B. Clear the boot mode
  • C. Disable node B boot mode
  • D. Reboot node B

Answer: A

 

NEW QUESTION 38
What method is used to power down a Dell EMC PowerStore system in a true emergency situation?

  • A. Remove base enclosure power cables
  • B. Run svc_node shutdown
  • C. Power Down Cluster in PowerStore GUI
  • D. Turn off the cabinet switches

Answer: D

 

NEW QUESTION 39
Which network traffic is encrypted using IPsec?

  • A. ICD network
  • B. OOB network
  • C. Inter-node network
  • D. ICM network

Answer: D

 

NEW QUESTION 40
What safety equipment is critical to have on hand to avoid equipment failure before replacing any components in a Dell EMC PowerStore array?

  • A. Rail Kit
  • B. Maintenance Kit
  • C. ESD Kit
  • D. Stabilization Kit

Answer: C

 

NEW QUESTION 41
What describes Dell EMC PowerStore X front-end cabling?

  • A. Storage and management use the same LACP bonded cable connection
  • B. Uses VLTi data switch interconnectivity to support vMotion networks
  • C. Uses internal VMware virtual switching and does not require a management network
  • D. Management and discovery use the same cables and connections as storage

Answer: D

Explanation:
"For PowerStore T model appliances, the individual ports within the system bond could be running in active/active mode or active/passive mode. This state depends on whether Link Aggregation Control Protocol (LACP) has been configured on the network switches. To ensure best resiliency and network performance, it is recommended to enable LACP on the network. For more information about configuring LACP for a PowerStore T model appliance, see the document PowerStore Guide for PowerStore T Models on the PowerStore Info Hub. For PowerStore X model appliances, there is no system bond and no LACP configuration is needed because the link aggregation and failover is handled by the virtual switches within the VMware hypervisor. "

 

NEW QUESTION 42
A Storage Administrator needs to connect through SSH to run svc commands. How is the SSH session configured?

  • A. NAS server IP address using port 22
  • B. NAS server IP address using port 26
  • C. Appliance IP address using port 22
  • D. Appliance IP address using port 26

Answer: A

 

NEW QUESTION 43
What describes the ICM and ICD networks?

  • A. Address type is persistent throughout the life of the cluster and CANNOT to be modified
  • B. Address type is dynamic and automatically reconfigured on discovery results
  • C. They are NOT encrypted
  • D. They are encrypted with IPsec

Answer: D

 

NEW QUESTION 44
Which network is used for internal communication?

  • A. NAD Network
  • B. Intra-Cluster Data
  • C. Inter-Node Network
  • D. Intra-Cluster Management

Answer: D

 

NEW QUESTION 45
Which LED combination shows a connected and working node?

  • A. power LED: blinking green fault LED: blue
  • B. power: LED: steady green fault LED: off
  • C. power LED: steady green fault LED: amber
  • D. power LED: blinking green fault LED: off

Answer: C

Explanation:
Explanation

 

NEW QUESTION 46
Refer to the exhibit.

What is the result of the network configuration show for a Dell EMC PowerStore T node A management port?

  • A. VLAN 1 passes untagged traffic, VLAN 1501 passes tagged traffic
  • B. VLAN 1 and VLAN 1501 pass untagged traffic
  • C. VLAN 1 passes tagged traffic, VLAN 1501 passes untagged traffic
  • D. VLAN 1 and VLAN 1501 pass tagged traffic

Answer: A

 

NEW QUESTION 47
......

DES-1241 Dumps Full Questions with Free PDF Questions to Pass: https://www.test4sure.com/DES-1241-pass4sure-vce.html